Self-built Electron app / 海外Tech Radar / JA
Test static analysis against a self-built app
ENGLISH SUMMARY
Test static analysis against a self-built app
A Japanese hands-on article checks REA's module and IPC findings against a four-file Electron-style app and records unresolved dynamic paths.
The question
How much of a known application structure can REA identify?
The workflow
- Prepare a small, self-built four-file application.
- Run analyze-javascript-application and inspect its JSON output.
- Compare findings with the known structure and record unresolved paths.
Findings & output
The author reports detecting a window, exposed API, and IPC channel, while some string-composed paths remained unresolved.
Evidence scope
This is static CLI inspection; the author did not test agent registration, native decompilation, or runtime behavior.
中文摘要
用自己写的应用,检验静态分析的边界
日文实践文章用一个四文件 Electron 风格应用核对 REA 的模块与 IPC 分析,同时记录动态路径没被解析的情况。
调查的问题
REA 能识别自己已知的应用结构到什么程度?
怎么做的
- 准备自己写的四文件应用。
- 运行 analyze-javascript-application,查看 JSON 结果。
- 用已知代码结构核对结果,记录漏掉的动态路径。
发现与产出
作者报告识别了窗口、暴露 API 与 IPC 通道;部分字符串拼接路径没有解析出来。
证据范围
是静态 CLI 调查,作者未验证 Agent 注册、原生反编译或实际运行行为。